Baseball and softball are, at their core, similar bat-and-ball sports where teams compete to score runs by hitting a ball and advancing around four bases. Baseball, established in the mid-19th century U.S., is typically played over nine innings. Conversely, softball was developed in 1887 as an indoor, faster-paced alternative with seven innings, a larger ball, and underhand pitching.
The World Baseball Softball Confederation (WBSC) is the world governing body for baseball and softball, recognized by the International Olympic Committee as the sole authority for both sports. Headquartered in Pully, Switzerland, the WBSC regulates international competitions, including the Olympic Games, Premier12, and World Cups, representing over 65 million athletes.
Baseball fields are significantly larger than softball fields, featuring 90-foot base paths, a 60-foot 6-inch pitcher's mound, and 300-400+ foot outfield fences. Conversely, softball fields have 60-foot base paths, a 43-foot (fastpitch) pitching distance, and 200-220 foot fences. Baseball uses a raised mound, while softball uses a flat dirt circle.
Dimension of a standard Baseball and softball field as below:
Baseball field Softball field
Typically, Baseball fields are larger than softball fields.
Each country or region has its own standards, and some international organizations also establish competition rules and lighting design rules. The primary standards referenced worldwide include:
(1). EN12193
(2). RP-6-22
(3). JGJ 153-2016
(4). AS 2526
(5). Baseball Competition Venue Guidelines from WBSC
(6). Softball Competition Venue Guidelines from WBSC
We will take European EN12193 standards requirements as an example for reference.
DIN EN12193 for sports lighting defines the minimum lighting requirements in tables for all sports.
Below is the basic requirements for non-televised Baseball/Softball fields:
For Baseball :
| Class | Square/infield Ehor ave lx | Square/infield U2 hor | Field/outfield Ehor Ave lx | Field/outfield U2 hor | Ra | Tcp | GR |
| Class I | 750lx | 0.7 | 500lx | 0.5 | >70 | 4000K | 50 |
| Class II | 500lx | 0.7 | 300lx | 0.5 | >60 | 4000K | 50 |
| Class III | 300lx | 0.5 | 200lx | 0.3 | >60 | 4000K | 55 |
For Softball :
| Class | Infield Ehor ave lx | Infield U2 hor | Outfield Ehor ave lx | Outfield U2 hor | Ra | Tcp | GR |
| Class I | 750lx | 0.7 | 500lx | 0.5 | >70 | 4000K | 50 |
| Class II | 500lx | 0.7 | 300lx | 0.5 | >70 | 4000K | 50 |
| Class III | 200lx | 0.5 | 100lx | 0.3 | >60 | 4000K | 55 |
Remarks: When grid points are outside the playing are they are not included in the calculation.
For the backstop area the same requirements apply as for the outfield.
Baseball pole location guidelines differ for structural foul poles and lighting poles. Foul poles are placed at the intersection of the outfield fence and foul lines, while lighting poles are strategically positioned around the field (4–8 poles) to ensure uniform, shadow-free illumination (minimum 70 ft tall).
Lighting Pole Guidelines
Number of Poles: Typically 6 to 8 poles for professional fields, and 4 to 6 for smaller fields.
Placement Strategy:
Behind Home Plate: To light the infield without creating glare.
Along Baselines: Positioned to illuminate the infield and outfield with minimal shadow.
Outfield Perimeter: Placed to light the outfield, facing inward.
Height: 70 to 120+ feet for regulation fields to improve light distribution and reduce glare.
Avoid: Placing poles directly in the line of sight of the catcher or in a 90° arc behind home plate, which can cause intense glare for outfielders.
The below figure is the recommended pole placement for a baseball/softball field. For smaller fields and recreational lighting requirements it usually uses 4 poles.
When providing lighting design solutions, we must first determine whether television broadcasts are required, as lighting specifications for televised events are significantly more stringent.
The primary distinction lies in the fact that for venues without television broadcasts, we need only consider horizontal illuminance. However, for venues with television broadcasts, our primary focus shifts to vertical illuminance. This difference results in significant variations in the lighting design solutions required for each scenario.
The Class I 750lx meets the illuminance requirements for professional competitions and training.
Due to variations in venue dimensions, customized designs are typically required for specific locations,
The following simulation is based solely on standard venues and is provided for reference only.
Solution: target infield 750lx outfield 500lx
Pole Qty: 6
Pole height: 25m
Floodlight Qty: 38 nos
GR max: 34
Wattage: 1500W/1800W
The illuminance requirements of Class II 500lx are very close to Class I 750lx,
The following simulation is based solely on standard venues and is provided for reference only.
Solution: target infield 500lx outfield 300lx
Pole Qty: 6
Pole height: 25m
Floodlight Qty: 30 nos
GR max: 34
Floodlight Wattage: 1500W
Class III 300lx is the minimum lighting requirement for recreational playing.
The following simulation is based solely on standard venues and is provided for reference only.
Solution: target infield 300lx outfield 200lx
Pole Qty: 4
Pole height: 23m
Floodlight Qty: 16 nos
Floodlight Wattage: 1000W/1200W
The sports flood lights available on the market can generally be divided into two categories: one is retrofit 1-to-1 type, typically designed with a one-piece heat sink, and the other is modular designed type, typically from 300W to 600W per module.
The design concept of R5 is to replace traditional HID one-to-one when refurbishment, particular attention should be paid to weight and dimensions.
There are 2 models which is designed with a one-piece heat sink, just different shapes. R5 is round while M6 is rectangular in shape.
R5 has 3 different sizes: 600-800W, 800W-1200W, 1200W-1500W
M6 also has 3 different sizes: 750W, 1000-1200W, 1500W
If the heat sink is used ACD12 die-casting alloy, the size and weight would be substantial, far exceeding that of traditional metal halide lamps, if maintaining the same dimensions would result in worse heat dissipation. Therefore, we employ a more reliable solution, using AL1060 cold-forging alloy.
| Model | Wattage range | Features |
R5 | 600W~800W 800~1200W 1200W~1500W | One-piece AL1060 Cold-forging heat sink with up to 237W/(m.K) standard thermal conductivity coefficient, which is double higher than ADC12 die-casting, which only has 96W/(m.K) |
| M6 | 750W 1000W-1200W 1500W | One-piece AL1060 Cold-forging heat sink with up to 237W/(m.K) standard thermal conductivity coefficient, which is double higher than ADC12 die-casting, which only has 96W/(m.K) |
There are a few modular designed Sports Flood lights in the market, from 300W to 600W per single module. Because it is more flexible and less tooling investments.
| Model | Wattage Range | Features |
M5 | 500W single module | ADC12 Die-casting |
| M8 | 800W single module | ADC12 Die-casting, M8 is larger in size and heavier in weight than M5 |
| M4 | 600W single module | Body material: AL1060 Cold-forging, M4 has better heat dissipation abilities than M5 and M8, hence M4 can be more compact under the same wattage comsuption which is very important for sports floodlights because of less EPA |
M5 is more economical than M8, while M4 has better heat dissipation management abilities due to AL1060 heat sink.