Baseball Field Lighting Design

Baseball and softball are, at their core, similar bat-and-ball sports where teams compete to score runs by hitting a ball and advancing around four bases. Baseball, established in the mid-19th century U.S., is typically played over nine innings. Conversely, softball was developed in 1887 as an indoor, faster-paced alternative with seven innings, a larger ball, and underhand pitching. 



;
Basic Knowledge

The World Baseball Softball Confederation (WBSC) is the world governing body for baseball and softball, recognized by the International Olympic Committee as the sole authority for both sports. Headquartered in Pully, Switzerland, the WBSC regulates international competitions, including the Olympic Games, Premier12, and World Cups, representing over 65 million athletes.

Dimension

Baseball fields are significantly larger than softball fields, featuring 90-foot base paths, a 60-foot 6-inch pitcher's mound, and 300-400+ foot outfield fences. Conversely, softball fields have 60-foot base paths, a 43-foot (fastpitch) pitching distance, and 200-220 foot fences. Baseball uses a raised mound, while softball uses a flat dirt circle.


Dimension of a standard Baseball and softball field as below: 


                                   Baseball field                                                                                    Softball field


Typically, Baseball fields are larger than softball fields.

Lighting Design Requirements

Each country or region has its own standards, and some international organizations also establish competition rules and lighting design rules. The primary standards referenced worldwide include:

(1). EN12193

(2). RP-6-22

(3). JGJ 153-2016

(4). AS 2526

(5). Baseball Competition Venue Guidelines from WBSC

(6). Softball Competition Venue Guidelines from WBSC

We will take European EN12193 standards requirements as an example for reference.

EN12193 Required

DIN EN12193 for sports lighting defines the minimum lighting requirements in tables for all sports.

Below is the basic requirements for non-televised Baseball/Softball fields:


For Baseball :

Class
Square/infield

Ehor ave lx

Square/infield

U2 hor

Field/outfield

Ehor Ave lx

Field/outfield

U2 hor

RaTcpGR
Class I750lx0.7500lx0.5>704000K50
Class II500lx0.7300lx0.5>604000K50
Class III300lx0.5200lx0.3>604000K55

For Softball :

Class      

Infield

Ehor ave lx  

Infield

U2 hor 

Outfield

Ehor ave lx  

Outfield

U2 hor  

Ra  Tcp  GR  
Class I750lx0.7500lx0.5>704000K50
Class II500lx0.7300lx0.5>704000K50
Class III200lx0.5100lx0.3>604000K55

Remarks: When grid points are outside the playing are they are not included in the calculation.

For the backstop area the same requirements apply as for the outfield.

 

Poles placement

Baseball pole location guidelines differ for structural foul poles and lighting poles. Foul poles are placed at the intersection of the outfield fence and foul lines, while lighting poles are strategically positioned around the field (4–8 poles) to ensure uniform, shadow-free illumination (minimum 70 ft tall). 


Lighting Pole Guidelines

Number of Poles: Typically 6 to 8 poles for professional fields, and 4 to 6 for smaller fields.

Placement Strategy:

Behind Home Plate: To light the infield without creating glare.

Along Baselines: Positioned to illuminate the infield and outfield with minimal shadow.

Outfield Perimeter: Placed to light the outfield, facing inward.

Height: 70 to 120+ feet for regulation fields to improve light distribution and reduce glare.

Avoid: Placing poles directly in the line of sight of the catcher or in a 90° arc behind home plate, which can cause intense glare for outfielders. 


The below figure is the recommended pole placement for a baseball/softball field. For smaller fields and recreational lighting requirements it usually uses 4 poles.

Lighting Design Simulations

When providing lighting design solutions, we must first determine whether television broadcasts are required, as lighting specifications for televised events are significantly more stringent.

The primary distinction lies in the fact that for venues without television broadcasts, we need only consider horizontal illuminance. However, for venues with television broadcasts, our primary focus shifts to vertical illuminance. This difference results in significant variations in the lighting design solutions required for each scenario.

Class I 750lx

The Class I 750lx meets the illuminance requirements for professional competitions and training.

Due to variations in venue dimensions, customized designs are typically required for specific locations,

The following simulation is based solely on standard venues and is provided for reference only.


Solution: target infield 750lx outfield 500lx

Pole Qty: 6

Pole height: 25m

Floodlight Qty: 38 nos

GR max: 34

Wattage: 1500W/1800W


Class II 500lx

The illuminance requirements of Class II 500lx are very close to Class I 750lx, 

The following simulation is based solely on standard venues and is provided for reference only.


Solution: target infield 500lx outfield 300lx

Pole Qty: 6

Pole height: 25m

Floodlight Qty: 30 nos

GR max: 34

Floodlight Wattage: 1500W


Class III 300lx

Class III 300lx is the minimum lighting requirement for recreational playing.

The following simulation is based solely on standard venues and is provided for reference only.


Solution: target infield 300lx outfield 200lx

Pole Qty: 4

Pole height: 23m

Floodlight Qty: 16 nos

Floodlight Wattage: 1000W/1200W

Recommended Models

The sports flood lights available on the market can generally be divided into two categories: one is retrofit 1-to-1 type, typically designed with a one-piece heat sink, and the other is modular designed type, typically from 300W to 600W per module.

One-piece heat sink

The design concept of R5 is to replace traditional HID one-to-one when refurbishment, particular attention should be paid to weight and dimensions.

There are 2 models which is designed with a one-piece heat sink, just different shapes. R5 is round while M6 is rectangular in shape.

R5 has 3 different sizes: 600-800W, 800W-1200W, 1200W-1500W

M6 also has 3 different sizes: 750W, 1000-1200W, 1500W

If the heat sink is used ACD12 die-casting alloy, the size and weight would be substantial, far exceeding that of traditional metal halide lamps, if maintaining the same dimensions would result in worse heat dissipation. Therefore, we employ a more reliable solution, using AL1060 cold-forging alloy.


ModelWattage rangeFeatures

R5


600W~800W

800~1200W

1200W~1500W  

One-piece AL1060 Cold-forging heat sink with up to 237W/(m.K) standard thermal conductivity coefficient, which is double higher than ADC12 die-casting, which only has 96W/(m.K) 
M6

750W

1000W-1200W 

1500W

One-piece AL1060 Cold-forging heat sink with up to 237W/(m.K) standard thermal conductivity coefficient, which is double higher than ADC12 die-casting, which only has 96W/(m.K) 

Modular design

There are a few modular designed Sports Flood lights in the market, from 300W to 600W per single module. Because it is more flexible and less tooling investments.


ModelWattage RangeFeatures

M5


500W single moduleADC12 Die-casting
M8800W single moduleADC12 Die-casting, M8 is larger in size and heavier in weight than M5
M4600W single moduleBody material: AL1060 Cold-forging, M4 has better heat dissipation abilities than M5 and M8, hence M4 can be more compact under the same wattage comsuption which is very important for sports floodlights because of less EPA

M5 is more economical than M8, while M4 has better heat dissipation management abilities due to AL1060 heat sink.

R5 1500W