Basketball Court Lighting Design

Basketball is built into the fabric of Springfield College. The game was invented by Springfield College instructor and graduate student James Naismith in 1891, and has grown into the worldwide athletic phenomenon we know it to be today.


Basketball is a fast-paced team sport where two teams of five players compete to score points by throwing a ball through a 10-foot-high hoop (the basket). Played on a court, the primary objective is to outscore the opponent within four quarters or two halves. Key skills include dribbling, passing, and shooting. 



;
Basic Knowledge

Dimension

Official basketball court dimensions vary by league, with the NBA/NCAA standard measuring 94ft x 50ft (28.65m x 15.24m), while FIBA courts are slightly smaller at 28m x 15m (91.86ft x 49.21ft). High school courts are typically 84 ft x 50 ft. All official courts feature a 10-foot high rim. 


Lighting Design Requirements

Each country or region has its own standards, and some international organizations also establish competition rules and lighting design rules. The primary standards referenced worldwide include :

(1). UEFA 2023

(2). FIFA 2020

(3). EN12193

(4). AS 2526

(5). RP-6-22

(6). JGJ 153-2016

We will take European EN12193 standards requirements as an example for reference.

EN12193 Required

DIN EN 12193 for sports lighting defines the minimum lighting requirements in tables for all sports.

Below is the basic requirements for non-broadcasting outdoor basketball courts:


Class Ehor Ave luxU2 horGR maxRa
Class I500lx0.755>70
Class II200lx0.655>60
Class III75lx0.555>60


Poles layout

Given the compact size of a single outdoor basketball court, two light poles are sufficient to meet recreational-level illuminance requirements. For higher illuminance level 4 light poles are sufficient.


Below figure is an example guidelines for outdoor basketball courts:


Lighting Design Simulations

Double Court 500lx

Below AGI32 simulation for Double court 500lx with 4 poles only for reference


Poles arrangement: 2-side

Poles Qty: 4

Poles height: 12m

Floodlights Qty: 12 nos

Floodlights wattage used: 1000W/1500W

Target average lux: >500lx

Target U2 hor: >0.7


Single court 500lx

Below AGI32 simulation for a single court 500lx with 4 poles only for reference.


Poles arrangement: 2-side

Poles Qty: 4

Poles height: 12m

Floodlights Qty: 8nos

Floodlights wattage used: 800W

Target average lux: >500lx

Target U2 hor: >0.7


Single court 200lx

Below AGI32 simulation for a single outdoor basketball 200lx with 4 poles only for reference.


Poles arrangement: 2-side

Poles Qty: 4

Poles height: 12m

Floodlights Qty: 4nos

Floodlights wattage used: 800W

Target average lux: >200lx

Target U2 hor: >0.7

Recommended Models

The sports flood lights available on the market can generally be divided into two categories: one is retrofit 1-to-1 type, typically designed with a one-piece heat sink, and the other is modular designed type, typically from 300W to 600W per module.

One-piece heat sink

The design concept of R5 is to replace traditional HID one-to-one when refurbishment, particular attention should be paid to weight and dimensions.

There are 2 models which is designed with a one-piece heat sink, just different shapes. R5 is round while M6 is rectangular in shape.

R5 has 3 different sizes: 600-800W, 800W-1200W, 1200W-1500W

M6 also has 3 different sizes: 750W, 1000-1200W, 1500W

If the heat sink is used ACD12 die-casting alloy, the size and weight would be substantial, far exceeding that of traditional metal halide lamps, if maintaining the same dimensions would result in worse heat dissipation. Therefore, we employ a more reliable solution, using AL1060 cold-forging alloy.


ModelWattage RangeFeatures
R5

600W~800W

800W~1200W

1200W~1500W

One-piece AL1060 Cold-forging heat sink with up to 237W/(m.K) standard thermal conductivity coefficient, which is double higher than ADC12 die-casting, which only has 96W/(m.K)
M6

750W

1000W~1200W

1500W

One-piece AL1060 Cold-forging heat sink with up to 237W/(m.K) standard thermal conductivity coefficient, which is double higher than ADC12 die-casting, which only has 96W/(m.K)


Modular design

There are a few modular designed Sports Flood lights in the market, from 300W to 600W per single module. Because it is more flexible and less tooling investments.


ModelWattage RangeFeatures
M5500W single moduleADC12 Die-casting
M8800W single moduleADC12 Die-casting
M4600W single moduleBody material: AL1060 Cold-forging, M4 has better heat dissipation abilities than M5 and M8, hence, M4 can be more compact under the same wattage comsuption which is very important for sports floodlights because of less EPA

M5 is more economical than M8, while M4 has better heat dissipation management abilities due to AL1060 heat sink.

R5 600W